Themis FCT AgentComing soon

Engineering assistant for functional test stations

Analyzes like a Functional Test Systems Architect. Asks, and waits for your confirmation before deciding.

Themis reads your customer's manufacturing package, turns every gap into a technical question, proposes the station and builds the NI TestStand sequence. You confirm every decision. Alongside it, three apps already running on TestStand stations.

Not on sale yet. Sign up, lock in founder pricing, and we'll contact you when demos open.

Themis FCT Agent

Customer spec · illustrative example · §4.2.2rev. C

With the unit powered at 13.5 V, the 5 V regulator output must be between 4.75 V and 5.25 V with a 500 mA load. settling?

  • BOM · InstrumentDC supply ≥ 13.5 V / 1 A
  • Access points + instrumentTP_5V, GND · DMM, DC volts
  • Limit4.75 V ≤ 5V_OUT ≤ 5.25 V
  • BOM · Load0.5 A on 5V_OUT
  • Technical questionSettling time before measuring?
  • TraceableEvery result cites §4.2.2, rev. C
  • Sequence step · TestStand 4.2.2 · Measure 5V_OUT with a 0.5 A load · 4.75–5.25 VDisabled until answered

Works with

  • NI TestStand
  • LabVIEW
  • .NET
  • Claude over MCP
  • Windows

From your customer's spec to the line's report. Themis FCT Agent designs the station and builds the sequence; Variant Manager, Report Analyzer and Report Viewer run alongside it in production with NI TestStand.

The Bravo-101 family

From the quote to the report.

Themis designs the station from the customer's spec. In production, three apps already on sale work alongside it: Variant Manager keeps each part number's values, Report Viewer opens one unit's report and Report Analyzer analyzes the whole line's. The same example datum travels the five stops.

Illustrative example

  1. Design

    Themis FCT Agent

    Reads the manufacturing package, asks what's missing, proposes the station and builds the TestStand sequence.

    Coming soon

    §4.2.2 → step: Step 4.2.2 · Measure 5V_OUT · 4.75–5.25 V

  2. Configure

    Variant Manager

    Keeps each part number's limits and variables outside the sequence and applies them at run time.

    Perpetual license

    limits per P/N: P/N 100-A · 4.75–5.25 V P/N 100-B · 4.85–5.15 V

  3. Test

    The station

    Your TestStand runs the sequence without the agent and without internet, and writes each unit's ATML report.

    Your TestStand

    5.02 V · PASS: Unit SN 0042 · 4.2.2 · 5.02 V · PASS

  4. Analyze

    Report Analyzer

    Reads hundreds of ATML reports: what fails most, on which station and whether every measurement is capable. PDF and Excel for your customer.

    Perpetual license

    4.2.2 trend: 4.2.2 across 500 units · capability · trend · Pareto

  5. Read

    Report Viewer

    Opens one unit's ATML report as a document and shows only what failed. Free.

    Free

    unit report: Report SN 0042 · 4.2.2 · 5.02 V · PASS

The apps

Three apps already running on TestStand stations.

Download them and try them with your own reports and sequences. Everything runs on your PC, with no account and no server or database to set up. Licenses are perpetual: you pay once.

  • Variant Manager clip with demo data: switching from BDB100A to BDB100B changes only the upper limit of 5V_OUT Voltage

    Variant Manager

    Perpetual license

    If you maintain a product family with several part numbers on the same sequence.

    One TestStand sequence for the whole family: every part number keeps its limits and variables outside the .seq, in a table your team can read, with a record of who changed what.

    • Switch part numbers and only their values change; the sequence is never written.
    • Duplicate the base variant to add a new part number.
    • History of who changed what, with the previous value, exportable to CSV.

    Interface in English and Spanish.

    from $ 999.00 MXN · one-time payment

    Download the free trial See details

  • Report Analyzer clip with demo data: Error Distribution with the tests that fail most

    Report Analyzer

    Perpetual license

    If you analyze production reports or build the capability study your customer asks for.

    Reads the native, lightweight ATML reports TestStand already writes and tells you what fails most, on which station, and whether every measurement is capable under your customer's standard.

    • Pick the folder: imports hundreds of reports, including files with several runs.
    • Cg/Cgk and Pp/Ppk capability under AIAG, VDA 5 or the standard your customer asks for.
    • Excel and PDF reports ready to send right after your first NPI validation.

    In our test: 1,400 reports in about 50 s. 14-day trial with every feature.

    from $ 1,999.00 MXN · one-time payment

    Download the free trial See details

  • Report Viewer clip with demo data: Failures only leaves just the test that failed

    Report Viewer

    Free

    If you need to read one unit's report away from the station: technicians, quality or the end customer.

    Opens TestStand's native ATML report on any Windows PC and takes you straight to the failure, with no TestStand installed.

    • One click on "Failures only": from hundreds of steps to the rows that failed.
    • The run on top and the step table with limits, value, comparison and status.
    • Several runs in one file: one unit at a time.

    No account, no network, and the report never leaves your PC.

    Download for free See details

How Themis works

From the manufacturing package to a station that keeps answering.

Themis workflow animation, in five steps PACKAGE THEMIS DELIVERABLES STATION spec.xlsx SOW.pdf requirements.docx screenshot.png Themis ? ! ? Technical questions Instrument BOM Load BOM Access BOM TestStand sequence COMING SOON Why does test 214 fail? What was decided, with evidence Themis workflow animation, in five steps PACKAGE spec.xlsx SOW.pdf requirements.docx screenshot.png Themis ? ! ? DELIVERABLES STATION Technical questions Instrument BOM Load BOM Access BOM TestStand sequence COMING SOON Why does test 214 fail? What was decided, with evidence

Step 1 of 5

The manufacturing package arrives.

Spec, SOW, requirements and screenshots, whatever the format.

Your station and your data stay yours.

Your data stays on your PC

The apps process everything locally, with no account and no telemetry. What Themis reads goes only to your AI provider (Claude, today), under your account.

The line never depends on us

The station runs without the agent and without internet. App licenses are perpetual and activate offline.

Built for NI teams

TestStand and LabVIEW. Report Analyzer and Report Viewer read ATML reports without TestStand installed.

Frequently asked questions

What people ask us before downloading or requesting a demo.

What is Bravo-101?

A Mexican company that builds software for functional test stations with NI TestStand. It sells products, not services: Themis FCT Agent (subscription software, coming soon) and three apps already running in production: Variant Manager and Report Analyzer, with perpetual licenses, and Report Viewer, which is free.

What does Themis FCT Agent do?

It reads your customer's manufacturing package (spec, SOW and requirements, whatever the format), turns every gap and contradiction into a technical question, proposes the station with its BOMs and builds the NI TestStand sequence with your own VIs and DLLs. It proposes and waits for your confirmation at every decision. It isn't on sale yet: request a demo and lock in founder pricing.

Which app do I need?

Variant Manager if you test a product family with several part numbers on the same sequence and want each one's limits and variables outside the .seq. Report Analyzer if you analyze hundreds of production reports: what fails most, on which station, and capability under your customer's standard. Report Viewer if you only need to read one unit's report away from the station. All three download free and you evaluate them with your own data.

Do I need NI TestStand installed?

Report Analyzer and Report Viewer don't: they read the ATML reports TestStand already writes, on any Windows PC. Variant Manager does run on the station, with NI TestStand 2025, because it reads your sequence and applies the values at run time. Themis needs LabVIEW and TestStand 2025 or later on the engineer's PC.

Do the apps work without internet and without an account?

Yes. All three apps process everything on your PC, with no server, no account and no telemetry, and the license activates offline. What Themis reads goes only to your AI provider (Claude, today), under your account; it never goes through Bravo-101 servers.

How do I buy and activate a license?

Download the app and try it with your data. When you're ready, buy the license in the store with a one-time payment; checkout doesn't ask for machine details. Then send your Device ID on Activate your license and get your key the next business day. If you change computers, we reissue the key at no cost.

What language are the apps and support in?

Variant Manager's interface is in English and Spanish. Report Analyzer and Report Viewer have an English interface. Support and documentation are in English and Spanish.

Learn

  1. Documentation

    Installation, activation and reference for every app.

    Go to the documentation

  2. Guides

    What we learned on the test floor, in writing.

    Read the guides

  3. Release checklist

    What to check before releasing a test station.

    Open the checklist